[. . . ] W10526074A COOKTOP SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING. [. . . ] Type of Gas Natural Gas: This cooktop is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas. if converting to LP gas , see the following “LP Gas Conversion” section. The model/serial rating plate located on the underside of the cooktop base has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier. LP Gas Conversion: Conversion must be done by a qualified service technician. No attempt shall be made to convert the cooktop from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. See the Gas Conversion instructions provided in the package containing literature. Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded. – 5 Gas Supply Line ■ Gas Pressure Regulator The gas pressure regulator supplied with this cooktop must be used. The inlet pressure to the regulator should be as follows for proper operation: Natural Gas: Minimum pressure: 5" (12. 5 cm) WCP Contact local gas supplier if you are not sure about the inlet pressure. A smaller size pipe on longer runs may result in insufficient gas supply. Usually, LP gas suppliers determine the size and materials used in the system. Flexible stainless steel tubing gas connector, designed by CSA to connect the cooktop to the rigid gas supply line. Burner Input Requirements ■ A ½" male pipe thread is needed for connection to the female pipe threads of the inlet to the cooktop pressure regulator. Do not kink or damage the flexible metal tubing when moving the cooktop. ■ Rigid pipe connection: The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the cooktop. All strains must be removed from the supply and fuel lines so cooktop will be level and in line. Input ratings shown on the model/serial rating plate are for elevations up to 2, 000 ft (609. Gas Supply Pressure Testing Gas supply pressure for testing regulator must be at least 1" water column pressure above the manifold pressure shown on the model/serial rating plate. Line pressure testing above ½ psi gauge (14" WCP) The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3. [. . . ] Manual gas shutoff valve Attach Cooktop to Countertop NOTE: This section applies only if you are using clamping brackets. If burner caps are not properly positioned, surface burners will not light. Clamping bracket (extends far enough beyond cooktop base to allow installation of clamping screws) E. 4 cm) clamping screws into the outermost hole in the clamping bracket. [. . . ]